Power Distribution Units (PDUs) › BN3500 Outlet Metered PDU: (24)C13, (4)C19 7.68kVA
BN3500 1U intelligent PDU with per-phase and per-outlet measurement, network-capable, modular, and rack-mountable. Image 1 of 1
BN3500 1U intelligent PDU with per-phase and per-outlet measurement, network-capable, modular, and rack-mountable.
BN3500 1U intelligent PDU with per-phase and per-outlet measurement, network-capable, modular, and rack-mountable.

BN3500 Outlet Metered PDU: (24)C13, (4)C19 7.68kVA

€2,808.00

Measurement per phase and outlet, network-capable and multifunctional

The BN3500 is an intelligent PDU. As with the BN3000, it enables professional energy and capacity management through network-capable measurements for each phase at PDU level. In addition, measurement values per outlet can be monitored.

Thanks to its compact design (1U), installing the BN3500 is flexible and space-saving, and therefore enables optimised cabling and air flow in the server rack.

Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN3500 can be integrated into third-party software systems via SNMP or Modbus TCP, for example.

Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

Furthermore, the flexible design of the PDU and different technology modules make a multitude of customised versions possible.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

Measurement per phase and outlet, network-capable and multifunctional

The BN3500 is an intelligent PDU. As with the BN3000, it enables professional energy and capacity management through network-capable measurements for each phase at PDU level. In addition, measurement values per outlet can be monitored.

Thanks to its compact design (1U), installing the BN3500 is flexible and space-saving, and therefore enables optimised cabling and air flow in the server rack.

Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN3500 can be integrated into third-party software systems via SNMP or Modbus TCP, for example.

Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

Furthermore, the flexible design of the PDU and different technology modules make a multitude of customised versions possible.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

  • The following measurement values are displayed for each phase and outlet on the illuminated display and in the integrated web server:

    • Current [A]

    • Neutral conductor current [A] for three-phase versions

    • Voltage [V]

    • Frequency [Hz]

    • Active power [kW]

    • Reactive power [kVAr]

    • Apparent power [kVA]

    • Active energy [kWh]

    • Reactive energy [kVArh]

    • Apparent energy [kVAh]

    • Power factor

    • Residual Current Monitoring (RCM type B) AC [mA] and DC [mA]

    • Surge Protection Device (SPD)

    • GPIO module

    • Housing colour

    • Temperature and air humidity sensors

    • Measurement per phase and outlet

    • Display with rotatable screen

    • Optional technology modules such as RCM type B

    • Cost benefit through Master/Slave cascading

    • A large number of protocols and interfaces supported

 

You Might Also Like

BN3500 Switched Outlet PDU: (24)C13, (6)C19 11kVA Compact PDU for 19” racks with C13/C19 outlets, modular design, durable aluminium build, and optional IEC Lock®
BN3500 Switched Outlet PDU: (24)C13, (6)C19 11kVA
€2,934.00
BN3500 Switched Outlet PDU: (24)C13, (6)C19 22kVA BN3500 1U intelligent PDU with per-phase and per-outlet measurement, network-capable, modular, and rack-mountable.
BN3500 Switched Outlet PDU: (24)C13, (6)C19 22kVA
€3,223.00